Dragana Miletic Dutina. Jack Waskito. Majeed ali. Elaya Raja. Rehan Yousaf. Fully calculated firefighting systems with EN standard. Isidoros Siderakis. Huzairi Sulaiman. Rohit Khanna. Thilak Raja. Pooja Khude. World Economic Forum. Elisha Thompson. Mahesh Rudragoudar. Popular in Physics. Hindreen Mohammed. SYahira HAzwani. Dipen K. Ashlesha Wadikhaye. Rizwan Ali Zia.

Lukman Kasim. Uploaded by Public Resource on May 26, Internet Archive's 25th Anniversary Logo. Search icon An illustration of a magnifying glass.

User icon An illustration of a person's head and chest. Sign up Log in. Web icon An illustration of a computer application window Wayback Machine Texts icon An illustration of an open book. Books Video icon An illustration of two cells of a film strip. Video Audio icon An illustration of an audio speaker. Audio Software icon An illustration of a 3. It does not specify which buildings require a sprinkler system.

The requirement to install a sprinkler system complying with NFPA 13 can usually be found in one of the following sources: building code; federal, state or local regulations; insurer's requirements; accreditation requirements; or owner's request. Yes, both sections would be applied cumulatively to the design area chosen from Figure This is shown in the following example: The application area determined from Figure As required by Section Therefore, the original density chosen from Figure Ensure that there are no other design area modifications required for the system being installed 3.

Can plastic pipe be used on a sprinkler system complying with NFPA 13? Section 6. This pipe must be installed in accordance with its listing limitations, including installation instructions. What is the limit for the calculated water velocity in a sprinkler system complying with NFPA 13? NFPA 13 does not specify a maximum limit for the calculated water velocity. As explained by A. NFPA 13 requires that sprinklers be installed throughout the premises in accordance with Section 4.

Section 8. This maximum dimension is the dimension measured from the sprinkler to the nearest edge of the obstruction. Isolated obstructions that are more than 24 inches away from standard upright and pendent sprinklers do not generally create a significant obstruction. Are sprinklers required in closets? There are limited exceptions specified in Section 8.

Can a supply control valve be installed downstream of the fire department connection? The confusion that brings about this question is usually caused by Section 8. These sections are necessary to differentiate the fire department connection from other types of water supplies.

Normally, a control valve is required before and after each check valve in a source of supply. The valves are required so that the check valve can be isolated and serviced.